在商层建筑中和大型防火卷帘门是不可或缺的防火设施,主要用来隔离较大空间成防火区,有效分隔各层区域的功能。防火卷帘门除了可以当普通门使用外,还有防火、隔烟、防止火势蔓延、保护人员疏散的特别功能。卷帘门厂家为您整理防火卷帘门分隔控制要求,如下慢慢讲来。
In commercial buildings and large shopping malls, fire-resistant rolling shutter doors are indispensable fire protection facilities, mainly used to isolate larger spaces into fire zones, effectively separating areas on each floor. Fire resistant rolling shutter doors not only can be used as ordinary doors, but also have special functions such as fire prevention, smoke isolation, preventing fire spread, and protecting personnel evacuation. The manufacturer of the rolling shutter door will organize the requirements for the separation and control of the fireproof rolling shutter door for you. Let's talk about it slowly as follows.
根据现场需要在防火卷帘门电控箱上设置
Set up on the electric control box of the fireproof rolling shutter door according to on-site needs
在高层建筑中,超级防火帷幕的有效防火分隔区域的选择和布局成为超级防火帷幕能否收获其有效防火功能的关键。
In high-rise buildings, the selection and layout of the effective fire separation area of the super fire curtain becomes the key to whether the super fire curtain can achieve its effective fire prevention function.
避免影响生活上下两层连为防火区
Avoid affecting daily life by connecting the upper and lower floors as a fire zone
需要在不影响正常生活和有效的防火隔离之间取得平衡。一般来说,高层建筑均设有上下连通走廊、开敞楼梯、自动扶梯、传送带等开口部分,应将上下两层连接为防火区,其硬快速卷帘门允许的较大建筑面积不应超过其建筑等级所规定的防火区建筑面积。
A balance needs to be struck between not affecting normal life and effective fire isolation. Generally speaking, high-rise buildings are equipped with openings such as up and down connecting corridors, open stairs, escalators, conveyor belts, etc. The upper and lower floors should be connected to form a fire zone, and the large building area allowed by hard and fast rolling shutter doors should not exceed the fire zone building area specified by their building grade.
当上下开孔设有耐火极限大于3.00h的防火帘或水幕等隔离设施时,面积不得叠加计算。房间与中庭相通的大厅、通道,卷帘门应隔有B类防火门或耐火极限大于3.00h的防火卷帘门。
When the upper and lower openings are equipped with isolation facilities such as fire curtains or water curtains with a fire resistance limit greater than 3.00 hours, the area shall not be calculated by superposition. The lobby, passage, and rolling shutter doors connecting the room and atrium should be separated by Class B fire doors or fire resistant rolling shutter doors with a fire resistance limit greater than 3.00 hours.
由此可见,防火卷帘门厂家建议防火卷帘的空间设置需要一定的知识,不能随便进行设计和安装。火区设置的质量直接影响到人们的生命财产。
From this, it can be seen that the manufacturer of fire resistant rolling shutter doors suggests that the space setting of fire resistant rolling shutter doors requires certain knowledge and cannot be designed and installed casually. The quality of setting up a fire zone directly affects the safety of people's lives and property.
本文的精彩内容由济南卷帘门提供知识提供,本网站还有很多的精彩内容,更多的内容您可以点击进入:http://www.jiahuawenti.cn我们有专门的客服为您解答问题
the exciting content of this article is provided by the knowledge provided by jinan rolling shutter door. there are also many exciting content on this website, and you can click to enter more content: http://www.jiahuawenti.cn we have dedicated customer service to answer your questions
下一篇:快速门无法打开是怎么回事? 上一篇:电动卷闸门故障及维修要注意什么?
阅读/ Recommended reading
- 济南遥控卷帘门:我来教你——卷闸门遥控器遇到故障怎么办? 2024-08-28
- 济南卷帘门:卷帘门(不锈钢款) 2024-07-25
- 济南卷帘门的故障维修与更换卷帘门注意事项 2024-07-19
- 选错济南卷帘门的后果居然有这么严重? 2024-07-13
- 电动卷帘门保养知识介绍 2024-06-14
- 彩钢板卷帘门基本介绍 2024-06-04
- 电动卷帘门遥控器配对方法 2024-06-17
- 济南卷帘门由哪几部分组成? 2024-05-24
济南卷帘门安装秘籍,让家居更有面子
2024-09-21
各位亲们好,今天我们要聊聊一个既实用又时尚的话题——卷帘门安装!也许你家的卷帘门已经陪伴了多年,或许你正打算为新居添置一扇感满满的卷帘门,无论出于何种情况,掌握正确的安装方法都...